论文标题

Nexo的$^{127} $ XE校准源的开发

Development of a $^{127}$Xe calibration source for nEXO

论文作者

Lenardo, B. G., Hardy, C. A., Tsang, R. H. M., Ondze, J. C. Nzobadila, Piepke, A., Triambak, S., Jamil, A., Adhikari, G., Kharusi, S. Al, Angelico, E., Arnquist, I. J., Belov, V., Bernard, E. P., Bhat, A., Bhatta, T., Bolotnikov, A., Breur, P. A., Brodsky, J. P., Brown, E., Brunner, T., Caden, E., Cao, G. F., Cao, L., Chana, B., Charlebois, S. A., Chernyak, D., Chiu, M., Cohen, J. R., Collister, R., Dalmasson, J., Daniels, T., Darroch, L., DeVoe, R., di Vacri, M. L., Ding, Y. Y., Dolinski, M. J., Echevers, J., Eckert, B., Elbeltagi, M., Fabris, L., Fairbank, D., Fairbank, W., Farine, J., Fu, Y. S., Gallina, G., Gautam, P., Giacomini, G., Gillis, W., Gingras, C., Gornea, R., Gratta, G., Harouaka, K., Heffner, M., Hein, E., Hößl, J., House, A., Iverson, A., Jiang, X. S., Karelin, A., Kaufman, L. J., Krücken, R., Kuchenkov, A., Kumar, K. S., Larson, A., Leach, K. G., Leonard, D. S., Li, G., Li, S., Li, Z., Licciardi, C., Lindsay, R., MacLellan, R., Masbou, J., McMichael, K., Peregrina, M. Medina, Mong, B., Moore, D. C., Murray, K., Nattress, J., Natzke, C. R., Ngwadla, X. E., Ni, K., Ning, Z., Orrell, J. L., Ortega, G. S., Ostrovskiy, I., Overman, C. T., Perna, A., Franco, T. Pinto, Pocar, A., Pratte, J. F., Priel, N., Raguzin, E., Ramonnye, G. J., Rasiwala, H., Raymond, K., Richardson, G., Richman, M., Ringuette, J., Rowson, P. C., Saldanha, R., Sangiorgio, S., Shang, X., Soma, A. K., Spadoni, F., Stekhanov, V., Sun, X. L., Thibado, S., Tidball, A., Todd, J., Totev, T., Tyuka, O. A., Vachon, F., Veeraraghavan, V., Viel, S., Wamba, K., Wang, Y., Wang, Q., Wei, W., Wen, L. J., Wichoski, U., Wilde, S., Wu, W. H., Yan, W., Yang, L., Zeldovich, O., Zhao, J., Ziegler, T.

论文摘要

我们使用$^{127} $ XE电子捕获源研究Nexo实验的校准技术。 Nexo是针对中性元β衰减($0νββ$)的下一代搜索,它将使用5吨的单片液体氙时间投影室(TPC)。氙气既用作源和检测介质,又将在$^{136} $ XE中富集至90%。为了优化事件重建和能量分辨率,需要进行校准以绘制位置和时间依赖性检测器响应。与$^{136} $^{136} $ xe $0νββ$相比,$^{127} $ XE的36.3天半衰期及其小$ Q $价值将使在正常操作中连续维持较小的活动,而无需引入其他背景,从而实现了额外的校准和监控器的响应。在这项工作中,我们描述了生产源和初步实验测试的过程。然后,我们使用仿真来投射这种源可以将空间校正校正到Nexo TPC的光和电荷响应的精度。

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

扫码加入交流群

加入微信交流群

微信交流群二维码

扫码加入学术交流群,获取更多资源