交替活跃的双人装备对腔内传热增强的转换时期的影响

Influence of the switch-over period of an alternately active bi-heater on heat transfer enhancement inside a cavity

论文作者

Pal, Anish, Biswas, Riddhideep, Sarkar, Sourav, Chakravarty, Aranyak, Mukhopadhyay, Achintya

论文摘要

对多核处理器的功率需求增加需要有效的热管理。本研究调查了平方腔内的自然对流传热,其相互活跃的双式装饰器模仿了双核处理器的两个核心。脉动热通量条件将在两个具有一定开关频率的离散加热器上实现。使用OpenFOAM研究了prandtl编号= 0.71的传热特性= 0.71,瑞利数量在10^3-10^6的范围内。将用于替代活性加热器配置的结果与稳定的单个加热器和稳定的双对称加热器的结果进行了比较。在所有切换期间,交替活跃的加热器构型比单个稳定加热器显示出更好的传热特性,并且在较低的转换期间比双对称加热器更好。但是,发现在切换期的较高值中,交替活跃加热器配置的最高温度会触及稳定的单个加热器的温度。使用比例分析确定了此阈值切换期。根据比例分析确定的阈值切换周期与从不同雷利数和加热器长度的数值模拟获得的结果一致。

Increasing power demands on multicore processors necessitate effective thermal management. The present study investigates natural convection heat transfer inside a square cavity with an alternately active bi-heater that mimics two cores of a dual-core processor. Pulsating heat flux condition is implemented on two discrete heaters with a certain switching frequency. The heat transfer characteristics have been investigated for Prandtl number =0.71 and Rayleigh number in the range of 10^3 - 10^6 using OpenFOAM. The results obtained for alternative active heaters configuration have been compared with that of the steady single heater and steady double-symmetric heaters subjected to the same heat flux. The alternately active heater configuration showed better heat transfer characteristics than a single steady heater for all switchover periods, and better than a double-symmetric heater for low switchover periods. However, it is found that for higher values of the switchover period, the maximum temperature of alternately active heaters configuration touches the temperature of steady single heater. This threshold switchover period has been determined using a scale analysis. The threshold switchover periods determined from scale analysis are consistent with the results obtained from numerical simulations for different Rayleigh numbers and heater lengths.

扫码加入交流群

加入微信交流群

微信交流群二维码

扫码加入学术交流群,获取更多资源