工业智能机器人作业车间防雷装置
检测技术规范
Technical specification for detection of lightning protection device
in industrial intelligent robot workshopDB43/T26—2023 2343
湖南省地方标准
ICS
CCS
07.060
A 47
发 布 湖南省市场监督管理局2023-0
5发布-29 2023-08实施-2
9
DB43/T 2623—2023
I
目 次
前言 ································ ································ ································ ························ Ⅲ
1 范围 ································ ································ ································ ····················· 1
2 规范性引用文件 ································ ································ ································ ······ 1
3 术语和定义 ································ ································ ································ ············ 1
4 基本规定 ································ ································ ································ ··············· 2
5 检测周期及检测项目 ································ ································ ································ 3
6 检测项目技术要求 ································ ································ ································ ··· 3
附录A(资料性) 部分检测仪器的主要性能和参数指标 ································ ····················· 5
附录B(规范性) 工业智能机器人作业车间防雷装置材料规格 ································ ············ 7
DB43/T 2623—2023
II
DB43/T 2623—2023
III
前 言
本文件按照 GB/T 1.1 —2020《标准化工作导则 第1部分:标准化文件的结构和起草规则》的规
定起草。
请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。
本文件由湖南省气象局提出。
本文件由湖南省气象标准化技术委员会归口。
本文件起草单位:湖南省湘潭市气象局。
本文件主要起草人:阳青山、雍志刚、陈代亮、李坦、张振、谭政、胡刚、尹宝蓉、邓洁琼、王文。
DB43/T 2623—2023
IV
DB43/T 2623—2023
1
工业智能机器人作业车间防雷装置检测技术规范
1 范围
本文件规定了工业智能机器人作业车间防雷装置检测的基本规定、检测周期及检测项目、检测项目
技术要求。
本文件适用于工业智能机器人作业车间防雷装置检测。
2 规范性引用文件
下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条 款。 其中, 注日期的引用文件,
仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本
文件。
GB 50057 建筑物防雷设计规范
GB 50343 建筑物电子信息系统防雷技术规范
GB/T 21431 建筑物防雷装置检测技术规范
GB/T 20867 工业机器人安全实施规范
3 术语和定义
下列术语和定义适用于本文件。
3.1
智能机器人 intelligent robot
具有依靠感知其环境、和 /或与外部资源交互、调整自身行为来执行任务的能力的机器人。
[GB/T 12643—2013,定义2.28]
3.2
工业智能机器人作业车间 industrial intelligent robot workshop
由一个或多个工业智能机器人完成其任务所需的作业场所,一般由控制室、生产线厂房组成。
3.3
防雷装置 lightning protection system (LPS)
用于减少闪击击于建 (构)筑物上或建 (构)筑物附近造成的物质性损害和人身伤亡,由外部防雷
装置和内部防雷装置组成。
[GB 50057 —2010,定义2.0.5]
3.4
接闪器 air-term ination system
由拦截闪击的接闪杆、接闪带、接闪线、接闪网以及金属屋面、金属构件等组成。
[GB 50057 —2010,定义2.0.8]
3.5
引下线 down -conductor system
DB43/T 2623—2023
2 用于将雷电流从接闪器传导至接地装置的导体。
[GB 50057 —2010,定义2.0.9]
3.6
接地装置 earth -termination systeam
接地体和接地线的总和,用于传导雷电流并将其流散入大地。
[GB 50057 —2010,定义2.0.10]
3.7
等电位连接 equipotential bonding
直接用连接导体或通过浪涌保护器将分离的金属部件、外来导电物、电力线路、通信线路及其他电
缆连接起来以减小雷电流在它们之间产生电位差的措施。
[GB 50343 —2012,定义2.0.12]
3.8
电磁屏蔽 electromagnetic shielding
用导电材料减少交变电磁场向指定区域穿透的措施。
[GB 50343 —2012,定义2.0.15]
3.9
电涌保护器 surge potective dlevice (SPD)
用于限制瞬态过电压和分泄电涌电流的器 件。它至少含有一个非线性元件。
[GB 50057 —2010,定义2.0.29]
3.10
防雷装置检测 lightning protection system check and measure
按照建筑物防雷装置的设计标准确定防雷装置满足标准要求而进行的检查、 测量及信息综合分析处
理全过程。
[GB/T 21431 —2015,定义3.23]
4 基本规定
4.1 防雷分类
工业智能机器人作业车间的防雷分类应按照 GB 50057 —2010第3章的方法确定。
4.2 防雷装置检测工作基本要求
4.2.1 取得雷电防护装置检测资质的单位,应当按照资质等级承担相应的雷电防护装置检测工作。雷
电防护装置检测单位及其人员从事雷电防护装置检测活动,应当遵守国家有关技术规范和标准。
4.2.2 防雷装置检测人员进入工业智能机器人作业车间进行检测工作时,宜遵守工业智能机器人作业
车间相关规定和要求。
4.2.3 防雷装置检测过程中一般受检单位应派专人陪同。受检单位陪同人员需熟悉现场环境状况、受
检测对象特性。双方在确认不致人员伤害和设备损坏的情况下方可开展检测工作。
4.2.4 防雷装置检测工作程序,一般宜按环境调查、方案制 定、现场检查与测试、原始数据记录整理、
计算分析与结果判定、出具检测报告的流程进行。
4.2.5 用于防雷装置检测的专用仪器设备应当经法定计量检定机构检定或者校准,并在有效期内。
4.2.6 接地电阻与土壤电阻率的测试,应在无降水、无积水、无冻土条件下进行。
DB43/T 2623—2023
3 4.2.7 检测人员宜当面向防雷装置受检单位现场负责人反馈检测情况及整改要求。宜对检测中发现问
题的理由和法律法规、标准规范依据予以解释。
4.3 注意事项
4.3.1 在测试接地电阻前,应首先测试土壤电阻率 ,土壤电阻率的测量方法应按照 GB/T 21431 —2015
附录B的方法确定。测试应选择在自然地表上进行,如地理条件限制,可选择在附近区域进行,但与待
测场所的中心间距不超过 500 m。土壤电阻率的测试地点应避开树木、河滩、地下金属物、接地装置、
高压线等。
4.3.2 测试仪和测试线的布设应远离高压线、变电所、大型通信设施等干扰源。当检测数据发生漂移
或数据失真时,应查找并远离干扰源重新布设测试电极和测试线。各测试线应避免缠绕,尽量保持平直
以减少感应环路面积。
DB43-T 2623-2023 工业智能机器人作业车间防雷装置检测技术规范 湖南省